Dati tecnici
Dati generali
Mounting type
  • Non-flush
Special type
  • Linearized
Particular characteristics
  • IO-Link dual channel
Type
  • Distance measuring
Measuring distance Sd
  • 0 … 10 mm
Resolution
  • < 0,022 mm (High Accuracy Mode)
Repeat accuracy
  • 0,022 mm
Adjustment
  • qTeach
  • IO-Link
Teach
  • Single point, Two point, Window
Linearity error
  • ± 40 µm (S = 0 ... 8 mm)
  • ± 60 µm (S = 0 ... 10 mm)
Temperature drift
  • ± 2 % (Full Scale)
Hysteresis
  • < 99 % (adjustable)
Power on indication
  • LED green
Output indicator
  • LED yellow
Output indicator Output 2
  • LED red
Dati elettrici
Response time (factory characteristic)
  • < 0,6 ms (High Speed Mode)
  • < 0,9 ms (Standard Mode)
  • < 2,3 ms (Robust Mode)
  • < 10,5 ms (High Accuracy Mode)
Switching frequency
  • 800 Hz (High Speed Mode)
  • 500 Hz (Standard Mode)
  • 150 Hz (Robust Mode)
  • 30 Hz (High Accuracy Mode)
Tensione di alimentazione +Vs
  • 8 … 30 VDC
Corrente assorbita max. (senza carico)
  • 25 mA
Circuito di uscita
  • PNP
  • Push-pull
  • IO-Link
Output current
  • 100 mA, sum of all outputs
Caduta di tensione Vd
  • <2,5 VDC
Protezione da cortocircuito
  • Si
Protezione dall'inversione di polarità
  • Si
Baud rate
  • 230.4 kBaud (COM 3)
Dati meccanici
Design
  • Rectangular
Material (sensing face)
  • SAN
Housing material
  • SAN
Dimension
  • 20 mm
Housing length
  • 41 mm
Connection types
  • Cable PVC, 2 m
Condizioni ambientali
Temperatura d'esercizio
  • -25 … +75 °C
Tipo di protezione
  • IP 67
Interface
  • IO-Link V1.1
Baud rate
  • 230.4 kBaud (COM 3)
Cycle time
  • ≥ 0,6 ms
Process data length
  • 32 Bit
Process data structure
  • Bit 0 = SSC1 (distance)
  • Bit 1 = SSC2 (distance)
  • Bit 3 = alarm
  • Bit 4 = SSC3 (frequency)
  • Bit 5 = SSC4 (counter)
  • Bit 16-31 = 16 Bit measurement
IO-Link port type
  • Class A
Adjustable parameters
  • Campo di misurazione
  • Switching point
  • Switching hysteresis
  • Measured value filtering
  • Time filters
  • LED status indicators
  • Output logic
  • Output circuit
  • Counter
  • Deactivate the sensor element
  • Find Me function
Additional data
  • Distance
  • Frequency
  • Operating cycles
  • Operating hours
  • Boot cycles
  • Tensione di funzionamento
  • Device temperature
  • Histograms

Modello 3D
Modello 3D

La creazione di modelli CAD richiede una registrazione esterna presso CADENAS.


software
Software

Scaricare
Data sheet
Operating Manual
EPLAN

Diagrammi
Resolution

Disegni
Drawings
Connection diagram

Accessori
Peripherals
The selected altAttribute does not exist! CM50I.PN-11261571

Articolo n..: 11261571

  • IP67 field IO-Link Master
  • 8 Ports, Class A/B, up to 4 A per port, 400 µs cycle time
  • Industrial Ethernet: PROFINET
  • IIoT: OPC UA, MQTT, JSON REST API
The selected altAttribute does not exist! CM50I.EC-11261572

Articolo n..: 11261572

  • IP67 field IO-Link Master
  • 8 Ports, Class A/B, up to 4 A per port, 400 µs cycle time
  • Industrial Ethernet: EtherCAT
  • IIoT: OPC UA, MQTT, JSON REST API
The selected altAttribute does not exist! CM50I.EIP-11261573

Articolo n..: 11261573

  • IP67 field IO-Link Master
  • 8 Ports, Class A/B, up to 4 A per port, 400 µs cycle time
  • Industrial Ethernet: EtherNet/IP
  • IIoT: OPC UA, MQTT, JSON REST API
The selected altAttribute does not exist! ZTEST-ALL.ANALOG
Test unit for sensors analog & digital

Articolo n..: 11084376

  • Output via display (V or mA) or LED (PNP/NPN)
  • Teach-in of sensors with integrated Teach- button
  • Connection for plug in power supply (available as accessory)
The selected altAttribute does not exist! SensControl
Wireless IO-Link Master

Articolo n..: 11214576

  • Integration of IO-Link sensors via USB
  • Including power supply (EU, KOR, USA, AUS, UK) and USB cable
The selected altAttribute does not exist! USB-C IO-Link Master

Articolo n..: 11234828

  • Compact IO-Link master perfectly suited for testing and getting to know IO-Link sensors
  • Simple power supply via USB-C
  • Quick and easy connection with the Baumer Sensor Suite
  • Specifically designed with the needs of engineering and service in mind

In alto