Dados técnicos
dados gerais
Mounting type
  • Quasi-flush
Special type
  • Linearized
Type
  • Distance measuring
Measuring distance Sd
  • 0 … 3 mm
Resolution
  • < 0,005 mm (High Accuracy Mode)
Repeat accuracy
  • 0,01 mm
Adjustment
  • IO-Link
Teach
  • Single point, Two point, Window
Linearity error
  • ± 10 µm (S = 0 ... 2 mm)
  • ± 90 µm (S = 0 ... 3 mm)
Temperature drift
  • ± 2 % (Full Scale: S = 0 ... 2 mm)
  • ± 6 % (Full Scale: S = 0 ... 3 mm)
Hysteresis
  • < 99 % (adjustable)
Dados Elétricos
Response time (factory characteristic)
  • < 1 ms
Switching frequency
  • 1,25 kHz
Voltage supply range +Vs
  • 8 … 30 VDC
Current consumption max. (no load)
  • 15 mA
Output circuit
  • PNP
  • Push-pull
  • IO-Link
Output current
  • 50 mA
Short circuit protection
  • Yes
Reverse polarity protection
  • Yes
Baud rate
  • 230.4 kBaud (COM 3)
Dados mecânicos
Design
  • Rectangular
Material (sensing face)
  • PBT
Housing material
  • Stainless steel
Dimension
  • 8 mm
Housing length
  • 24,6 mm
Connection types
  • Flylead connector PUR M8, L=200 mm
Tightening torque max.
  • 0,8 Nm
Condições ambientais
Operating temperature
  • -20 … +70 °C
Protection class
  • IP 67
Interface
  • IO-Link V1.1
Baud rate
  • 230.4 kBaud (COM 3)
Cycle time
  • ≥ 0,6 ms
Process data length
  • 32 Bit
Process data structure
  • Bit 0 = SSC1 (distance)
  • Bit 1 = SSC2 (distance)
  • Bit 3 = alarm
  • Bit 4 = SSC3 (frequency)
  • Bit 5 = SSC4 (counter)
  • Bit 16-31 = 16 Bit measurement
IO-Link port type
  • Class A
Adjustable parameters
  • Measuring range
  • Switching point
  • Switching hysteresis
  • Measured value filtering
  • Time filters
  • Output logic
  • Output circuit
  • Counter
  • Deactivate the sensor element
Additional data
  • Distance
  • Frequency
  • Operating cycles
  • Operating hours
  • Boot cycles
  • Operating voltage
  • Device temperature
  • Histograms

Modelo 3D
Modelo 3D

A criação de modelos CAD requer um registro externo no CADENAS.


Software
Software

Transferências
Data sheet
Operating Manual
Certificates / approvals
EPLAN

Diagramas
Resolution

Desenhos
Drawings
Connection diagram
Pin assignment

Acessórios
Peripherals
The selected altAttribute does not exist! CM50I.PN-11261571

Artigo nº: 11261571

  • IP67 field IO-Link Master
  • 8 Ports, Class A/B, up to 4 A per port, 400 µs cycle time
  • Industrial Ethernet: PROFINET
  • IIoT: OPC UA, MQTT, JSON REST API
The selected altAttribute does not exist! CM50I.EC-11261572

Artigo nº: 11261572

  • IP67 field IO-Link Master
  • 8 Ports, Class A/B, up to 4 A per port, 400 µs cycle time
  • Industrial Ethernet: EtherCAT
  • IIoT: OPC UA, MQTT, JSON REST API
The selected altAttribute does not exist! CM50I.EIP-11261573

Artigo nº: 11261573

  • IP67 field IO-Link Master
  • 8 Ports, Class A/B, up to 4 A per port, 400 µs cycle time
  • Industrial Ethernet: EtherNet/IP
  • IIoT: OPC UA, MQTT, JSON REST API
The selected altAttribute does not exist! USB-C IO-Link Master

Artigo nº: 11234828

  • Compact IO-Link master perfectly suited for testing and getting to know IO-Link sensors
  • Simple power supply via USB-C
  • Quick and easy connection with the Baumer Sensor Suite
  • Specifically designed with the needs of engineering and service in mind
The selected altAttribute does not exist! SensControl
Wireless IO-Link Master

Artigo nº: 11214576

  • On-site configuration and monitoring of IO-Link devices (sensors/actuators)
  • Communication via WLAN, Bluetooth LE and IO-Link
  • Power supply by integrated rechargeable battery
  • Increased mobility and easy to use via SensControl app

Para o topo